Techinical DataGHESS 9.8-14.4-TH
System Parameter
Nominal Capacity [kWh]14.4
Usable Capacity [kWh]11.52 @80% DoD
Number of Battery Modules6
Installation TypeSeparate-mounted
Warranty [year]5 - 10 (optional)
Grid connection3-phase
Life Cycle6000 @80% DoD
Input - DC (Battery)
Max. Charging / Discharging Power [W]6000 / 6000
Operating Voltage Range [V]285 - 320
Max. Charging / Discharging Current [A]20 / 20
Input - DC (PV)

Max. Input Power [W]

9800

MPPT Voltage Range [V]

200 - 800

Rated Voltage [V]

670

Max. Current [A]

2 * 14

Max. Shorted Current [A]2 * 17.5
MPP Tracker2
Output- AC (Loads/Grid)

Rated Power [W]

8000

Output Voltage Range [V]

3N - 400

Max. Current Output [A]

15.2

Power Factor with Rated Power

[-0.8, +0.8]

THD

<3%
Output - AC (Backup Power)

Rated AC Power Output [W]

5600

Rated Voltage Output [V]

3N - 400
Rated Frequency Output [Hz]50
THD<3%
Efficiency
Round-trip Efficiency (Include Batteries)92%

General Data


Operating Temperature Range [℃]-10 to +50 (>45 derating)
Relative Humidity≤95%  (no condensing)
Altitude [m]≤2000
IP Protection ClassIP 20 (battery cabinet) / IP 65 (inverter)
CoolingForced air cooling
Noise [dB]<55
InterfaceCAN / RS485 / WIFI
Dimension (W * H * D) [mm]

540 * 670 * 275 (inverter)

563 * 1610 * 400 (battery cabinet)

DisplayLCD 
Energy Management SystemsGMDE EMS
Certification & Standard

VDE-AR-N 4105/08.11, E DIN VDE V 0124-100/10.13, IEC/EN 62109-1:2010, 

IEC/EN 62109-2:2011, IEC/EN 61000-6-2:2005, IEC/EN 61000-6-4:2007+A1

Protective Devices
AC Short-circuitY
DC Reverse Polarity ProtectionY
DC SwitchY
Surge ProtectionY


Optimize Energy Use


Solar Self-consumption


Clean Backup Power

GMDE energy storage system enables you to participate in utility demand response programs and control your electricity consumption during seasonal peak price periods. Using stored energy allows you to manage when and how to use your energy to reduce costs and environmental impact.


Conventionally the surplus electricity generated by home solar system is fed into the grid. However, most homes use a significant amount of electricity in the evening, after their solar panels stop producing. With GMDE energy storage system, excess power is stored in battery and clean energy can be used on-site even when the sun is not shining.


Backup power is a key benefit of GMDE energy storage system. Solar systems won’t work when the grid goes down. With our solution, you can use your solar power when there is an outage with backup power being recharged every day. With sustainable backup power, you rely less on the grid and have an eco-friendly alternative to a fossil fuel burning generator.


Say goodbye to peak energy rates

image.png


At daytime:

After supplying power to meet the loads demand, your system is charged by the sun. When your system is fully charged, excess power is fed into the grid.

At night: 

Your system works throughout the night. After your peak demand you can choose to replenish from the grid at off-peak rates for the morning.

When short of sunlight: 

Solar panels alone can’t meet the high evening demand. The system automatically supplies the shortfall by charging from grid.